COM Class Factory Errors may appear in Batch Manager when running workflows using text-recognition.  Typical symptoms of this are blank text layers or KeyFree OCR not recognizing any text on a text searchable document in GS LAN. COM Errors (Component Object Model) can be responsible for this. If these errors reside on the server, we're typically dealing with a DCOM issue, whereas client issues tend to be simple COM issues. 

As far as GlobalSearch is concerned, COM issues tend to be very simple permissions errors.

Fixing DCOM & COM Permissions isn’t difficult. Follow the steps below:

Set DCOM/COM Permissions Manually

  1. Open CMD prompt as an administrator
  2. Run: cd C:\WINDOWS\System32
  3. Run: regsvr32 /n /i:"C:\getsmart\inc" "C:\getsmart\ocr\frengine.dll"
  4. Run: mmc comexp.msc /64
  5. Open "Computers" – "My Computer" – "DCOM Config" – "ABBYY Finereader Engine Loader"
    1. Note that by default they are presented in alphabetical order
  6. Right click on "ABBYY Finereader Engine Loader" and select properties
  7. Select the Security tab in the properties window
  8. Select customize for all 3 options and add the SSAdministrator user to the security with full permissions

The default location for the GetSmart folder in step 3 is the C: drive. If the GetSmart folder is located on a different drive, please update the command accordingly


To Set COM on a client:

  1. Open CMD prompt as an administrator
  2. Run: cd C:\WINDOWS\System32
  3. Run: regsvr32 /n /i:"C:\Program Files (x86)\Common Files\Square9\GetSmart\inc" "C:\Program Files (x86)\Common Files\Square9\GetSmart\ocr\frengine.dll" 
  4. Run: mmc comexp.msc /64
  5. Open "Computers" – "My Computer" – "DCOM Config" – "ABBYY Finereader Engine Loader"
    1. Note that by default they are presented in alphabetical order
  6. Right click on "ABBYY Finereader Engine Loader" and select properties
  7. Select the Security tab in the properties window
  8. Select customize for all 3 options and add the SSAdministrator user to the security with full permissions

The default location for the GetSmart folder in step 3 is the C: drive. If the GetSmart folder is located on a different drive, please update the command accordingly